1. How to check the error code from Pimax Play?
Open the Pimax Play interface, and click the blue icon after "Disconnect" with the mouse.
2. Error code 105XX
a. Error code 10500
Cause: USB not recognized when connecting the headset to the computer
Solution:
· Please make sure that the USB head of the DP cable is connected to a USB port on the PC with a USB3.0
· For laptops, please make sure that the computer interface supports direct connection to the independent graphics card and the adapter used supports DP1.4
· Please make sure that the DP cable on the head display is plugged in tightly and not dislocated (as shown below)
· Please make sure that the power adapter is plugged into a power source with an appropriate voltage range and the switch is turned on.
· Please make sure that the power adapter interface is correctly connected to the DP cable
b. Error code 10517
Solution: Restart the headset and restart the computer
c. Error code 10518
Solution: Delete the directory (%programdata%\pimax\slam) and restart the service
3. Error code 106XX
a. Error code 10600
Cause: Graphics card DP is not recognized/using a high-resolution or refresh rate monitor
Solution:
· Please make sure that the DP port of the data cable is connected to the DP port of the independent graphics card
· Please make sure that the DP cable on the head display is plugged in tightly and not dislocated (as shown below)
· Graphics card driver problem, please update the driver from the graphics card's official website
· Lowering the resolution and refresh rate of the monitor
b. Error code 10632/10636
Cause: Graphics card or DP cable problem
Solution:
· Re-plug the display cable
· Install the graphics driver
· Restart the operating system
3. Error code 109XX
a. Error code 10900
Cause: The helmet DP port is connected to the integrated graphics card/the graphics card does not support direct connection mode/the graphics card driver is too old
(The Type-C port on the laptop does not support graphics card signal transmission)
Solution:
· Plug the helmet display device into the independent graphics card
· Replace the graphics card driver
· Check the graphics card model and confirm whether it is lower than the minimum graphics card requirement
· For laptops, please contact the merchant to confirm whether the Type-C interface supports direct output of the graphics
b. Error code 10932
Cause: Graphics card or DP cable problem/Dual graphics cards cannot be connected
Solution:
· Re-plug the DP cable
· Perform a clean installation from the GPU driver
· Dual graphics cards require the headset DP cable and the monitor cable to be connected to the same graphics card
c. Error code 10933
Cause: The device has been used
Solution:
· Replug the DP port
· Switch the DP port or restart the computer
d. Error code 10934
Cause: Integrated/core graphics card detected
Solution: Disable the integrated/core graphics card from the BIOS setting, not from the device manager.
· Disabling Integrated Graphics in BIOS Guide
e. Error code 10935/10936
Solution:
· Replace the data cable or DP port
· Perform a clean installation from the GPU driver
· Reinstall the latest Pimax Play
f. Error code 10938
Cause: Exceeding the graphics card bandwidth
Solution:
· Remove extra display devices
· Reduce display resolution and refresh rate
4. Error code 20XXX
a. Error code 20000
Solution:
· Re-plug the USB
· If there is a problem with the operating system USB driver, you can try to uninstall the driver and download the driver from the motherboard official website.
b. Error code 20100
Cause: Pimax Play file installation error
Solution: Reinstall the Pimax Play
c. Error code 20300/20400
Cause: Headset device acquisition failed
Solution: Restart the client and reinstall the client
d. Error code 20800
Cause: VR service connection failed
Solution: Restart the service
e. Error code 29001
Cause of failure: Pimax Play internal data communication is abnormal
Solution: Restart the service
5. Error code 30XXX
a. Error code 30000
Cause: Pimax Play service is abnormal
Solution: Restart the client and reinstall the Pimax Play
b. Error code 30101
Cause: Algorithm problem
Solution: Delete the directory (%programdata%\pimax\slam) and restart the service
c. Error code 30202/30204
Cause: Pimax Play and headset communication abnormality
Solution: Please wait. If the waiting time is too long, please restart the headset and restart the service.
d. Error code 30205
Cause: Communication between Pimax Play and the headset timed out
Solution: Restart the computer or reinstall the Pimax Play